LaserKote Volume Chart for Thin Film Coatings (60° Hexagon)

These LaserKote™ volume charts outline examples of volumes to be used with various coating materials based on percent solids. These should be used only as guides. Actual coating specification should be reviewed and reconfirmed with each application.

60° Hexagon LaserKote™ Volume Chart
(for Thin Film Coatings)

 

Approximate Depth Range
(in microns*)

Final Volume Range
(in BCMs**)

 

Cell Count

Min.

Max.

Min.

Max.

Minimum Roll Diameter Tolerance

120

35

48

9.9

12.5

0.0040

140

29

41

7.6

10.6

0.0040

180

19

31

5

8

0.0040

200

17

28

4.5

7.1

0.0030

250

15

24

3.9

6.2

0.0030

300

13

20

3.4

4.9

0.0030

400

10

16

2.4

3.8

0.0020

500

9

13

2.3

3.2

0.0020

600

7

11

1.7

2.6

0.0020

700

6

10

1.5

2.3

0.0020

800

5

9

1.2

1.8

0.0020

 

*Microns are a metric unit of measurement. There are 25.4 microns in .001"

**BCMs are billion cubic microns per square inch of surface area

Note: All volumes manufactured and measured using Echotopography™. All screens will be polished after engraving as indicated in the chart above. Minimum OD tolerance must be observed as diameter increase does not allow for tighter tolerances.

 

 

 

 

 

 

 

© 2005-2006, Harper Corp. of America; All Rights Reserved  

Terms & Conditions of Use



 

 
 

Anilox Rolls
Carbon Fiber
Platinum®XLT™
Platinum
The Terminator
Coating Rolls
LaserKote™
NW Stock Rolls
Rapid Delivery!
EchoExpress
Volume Charts
PlatinumXLT™
Inch or Metric
LaserKote™
60° Hexagon
Trihelical
45° Quad
Recommended Inventories:
Narrow Web
Wide Web
Corrugated
Learn About:
Anilox Care & Cleaning
Specifying the
Right Anilox Roll
Anilox Damage Prevention
Roll Surface Analysis
Process Printing
Roll Specs
Line Printing Roll Specs
Understanding:
Anilox Line Screen
Anilox Volume
Plate Dot vs. Anilox Cell Models